Share:

US014 over MISSOURI RV

Map

Coordinates:
+44.37207, -100.36673
44°22'19" N, 100°22'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US014 over MISSOURI RV
Structure number:000000033100118
Location:HUGHES - STANLEY CO LINE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:234.9 ft. [71.6 m]
Total length:1659.2 ft. [505.7 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:66.6 ft. [20.3 m]
Vertical clearance below bridge:29.5 ft. [9.0 m]
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:10
Main spans material:Steel continuous [4]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:15,450 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:35.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$300,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018PoorFairPoorPoor1545035.8
August 2017FairFairFairFair1545051.8
August 2016FairFairFairFair1545051.8
August 2015FairFairFairFair1533651.8
July 2014FairFairFairFair1514051.8
July 2013FairFairFairFair1512054.8
July 2012FairFairFairFair1590054.8
September 2011FairFairFairFair1590054.8
May 2010FairFairFairSatisfactory1530054.8
June 2009FairFairFairSatisfactory1490054.8
May 2008PoorFairFairPoor1409038.8
July 2007PoorFairFairPoor1206838.8
July 2006PoorFairFairPoor1404038.8
July 2005PoorFairFairPoor1404038.8
July 2004PoorFairFairPoor1403038.8
April 2003PoorFairPoorPoor1374038.8
May 2002PoorFairSeriousFair1317521.8
July 2001PoorFairSeriousFair1534521.8
June 2000FairFairFairFair1408054.8
June 1999FairFairFairFair1455554.8
June 1998FairFairFairSatisfactory1458554.8
August 1997FairSatisfactoryFairGood1418055.8
July 1996FairSatisfactoryFairGood1433055.8
July 1995FairSatisfactoryFairGood1406055.5
June 1994FairSatisfactorySatisfactoryGood1409073.2
May 1993FairSatisfactorySatisfactoryGood1257074.4
February 1992FairSatisfactorySatisfactoryGood1201566.5
April 1991FairFairFairGood1066056.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.6,6363,7802,6811750
Steel Protective Coatingsq. ft.171,545169,10670001,739
Steel Stringerlinear ft.6,6366,51073530
Steel Protective Coatingsq. ft.18,88318,798291739
Deck
Reinforced Concrete Decksq. ft.110,32494,7938,9586,5730
Wearing Surfacessq. ft.110,32462,67647,64800
Superstructure
Steel Floor Beamlinear ft.4,3684,30915440
Steel Protective Coatingsq. ft.41,31741,2726039
Substructure
Reinforced Concrete Columneach3603600
Reinforced Concrete Abutmentlinear ft.1809345420
Reinforced Concrete Pile Cap/Footinglinear ft.57602163600
Steel Pileeach146001460
Reinforced Concrete Pier Caplinear ft.57620936610
Joints
Open Jointlinear ft.2390541850
Bearings
Movable Bearingeach40027130
Steel Protective Coatingsq. ft.8167760040
Fixed Bearingeach1201200
Steel Protective Coatingsq. ft.4224100012
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.4,97704,97700
Steel Protective Coatingsq. ft.122,59298,07412,259012,259
Reinforced Concrete Bridge Raillinear ft.4,9773,2471,4902400