Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 7 over PLEASANT RUN CREEK
Structure number:28SR0070025
Location:IN PULASKI CITY LIMITS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:27.9 ft. [8.5 m]
Total length:28.9 ft. [8.8 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:52.2 ft. [15.9 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1938
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:4,130 [as of 2017]
Truck traffic:9% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:90.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairSatisfactoryGoodSatisfactory413090.7
November 2015FairSatisfactoryGoodSatisfactory433090.2
November 2013FairGoodGoodSatisfactory388091.2
November 2011GoodVery GoodGoodGood501087.6
November 2009FairSatisfactoryGoodSatisfactory465089.5
November 2007FairSatisfactorySatisfactorySatisfactory471086.4
November 2005FairSatisfactorySatisfactorySatisfactory517084.2
November 2003FairSatisfactorySatisfactorySatisfactory227091.9
November 2001FairSatisfactorySatisfactorySatisfactory610082.1
December 1999FairSatisfactorySatisfactorySatisfactory430085.3
January 1998FairSatisfactorySatisfactorySatisfactory436085.1
October 1995FairSatisfactorySatisfactorySatisfactory436085.1
April 1993FairSatisfactorySatisfactorySatisfactory585081.0
May 1991FairSatisfactorySatisfactorySatisfactory545081.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.261261000
Deck
Reinforced Concrete Decksq. ft.1,56001,56000
Wearing Surfacessq. ft.1,1601,160000
Substructure
Reinforced Concrete Abutmentlinear ft.104010400
Bearings
Fixed Bearingeach1801800
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5805800