Share:

FAP 1 over CALFKILLER RV & DEMPS RD

Map

Coordinates:
+35.86798, -85.47465
35°52'05" N, 85°28'29" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 1 over CALFKILLER RV & DEMPS RD
Structure number:93SR0010010
Location:5 MI E OF SR285 JCT
Purpose:Carries highway over highway and waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:136.2 ft. [41.5 m]
Total length:592.9 ft. [180.7 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:25°
Owner:State Highway Agency [01]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:5,910 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018GoodGoodGoodGood591098.7
April 2016GoodGoodGoodGood632099.7
April 2014GoodGoodGoodGood541099.8
March 2012GoodVery GoodVery GoodGood551099.7
March 2010GoodVery GoodVery GoodGood588099.7
April 2008GoodVery GoodVery GoodGood511099.8
February 2006GoodVery GoodVery GoodGood518099.8
February 2004GoodVery GoodVery GoodGood553099.7
January 2002GoodVery GoodVery GoodGood506099.8
January 2000GoodVery GoodVery GoodGood573099.7
January 1998GoodVery GoodVery GoodGood456099.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.2,9632,963000
Deck
Reinforced Concrete Decksq. ft.26,07026,066400
Substructure
Reinforced Concrete Columneach87100
Reinforced Concrete Abutmentlinear ft.9889900
Reinforced Concrete Pier Caplinear ft.176176000
Joints
Strip Seal Jointlinear ft.4949000
Pourable Jointlinear ft.4949000
Bearings
Elastomeric Bearingeach3027120
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,1851,1691600