FM 1448 over INDIAN CREEK
Map
Coordinates:
+33.00383, -95.2002833°00'14" N, 95°12'01" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FM 1448 over INDIAN CREEK |
Structure number: | 010810138001003 |
Location: | 1.3 MI W OF FM 115 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 9.8 ft. [3.0 m] |
Total length: | 32.2 ft. [9.8 m] |
Roadway width between curbs: | 33.5 ft. [10.2 m] |
Deck width edge-to-edge: | 36.1 ft. [11.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1990 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: January 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 650 [as of 2013] |
Truck traffic: | 9% of total traffic |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 97.8 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
January 2017 | Good | 7 out of 10 | 650 | 97.8 |
February 2015 | Good | 7 out of 10 | 650 | 96.8 |
May 2013 | Good | 7 out of 10 | 550 | 97.9 |
May 2011 | Good | 7 out of 10 | 630 | 98.8 |
May 2009 | Good | 7 out of 10 | 710 | 98.8 |
April 2007 | Good | 7 out of 10 | 810 | 99.8 |
April 2005 | Good | 7 out of 10 | 690 | 98.8 |
June 2003 | Good | 7 out of 10 | 700 | 99.8 |
May 2001 | Good | 7 out of 10 | 550 | 99.8 |
May 1999 | Good | 7 out of 10 | 620 | 99.8 |
July 1997 | Good | 7 out of 10 | 680 | 99.8 |
December 1994 | Good | 9 out of 10 | 640 | 99.8 |
August 1992 | Good | 9 out of 10 | 570 | 99.8 |
July 1990 | Good | 9 out of 10 | 510 | 99.8 |