Share:

FM 1731 over CATFISH DRAW

Map

Coordinates:
+34.53213, -102.88595
34°31'56" N, 102°53'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 1731 over CATFISH DRAW
Structure number:051850163404004
Location:0.5 MI N OF US 60
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:9.8 ft. [3.0 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:36.4 ft. [11.1 m]
Owner:State Highway Agency [01]
Year built:1974
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:230 [as of 2013]
Truck traffic:23% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2015Good7 out of 1023098.7
August 2011Fair6 out of 1021096.7
August 2007Good7 out of 1018096.8
January 2004Good7 out of 1022097.7
February 2000Fair6 out of 1018097.7
November 1995Good7 out of 1028097.6
February 1991Good8 out of 1029099.6