Share:

US 62 E FRTG RD over SULPHUR SPRINGS DRAW

Map

Coordinates:
+33.05939, -102.41647
33°03'34" N, 102°24'59" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 62 E FRTG RD over SULPHUR SPRINGS DRAW
Structure number:052230022801002
Location:1.05 MI NE OF FM 213
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:5.9 ft. [1.8 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Owner:State Highway Agency [01]
Year built:1933
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2015]
Truck traffic:21% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:89.8

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2017Good7 out of 1010089.8
November 2015Good7 out of 1010089.5
November 2013Good7 out of 1010089.5
November 2011Fair6 out of 1010088.5
November 2009Good7 out of 1010088.8
November 2007Good7 out of 1010088.8
January 2004Good7 out of 10240086.3
February 2000Good7 out of 10245071.8
October 1995Good7 out of 10225072.9
February 1991Good8 out of 10205085.4
August 1988Good8 out of 10215085.4