CR 2089 over SWINDLER CREEK
Map
Coordinates:
+31.00088, -93.6119731°00'03" N, 93°36'43" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | CR 2089 over SWINDLER CREEK |
Structure number: | 201760AA0210001 |
Location: | 0.10 MI W OF FM 2991 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 58.1 ft. [17.7 m] |
Total length: | 59.1 ft. [18.0 m] |
Roadway width between curbs: | 14.1 ft. [4.3 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Owner: | County Highway Agency [02] |
Year built: | 2008 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 30 [as of 2015] |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 59.7 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $4,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Good | Satisfactory | Very Good | 30 | 59.7 |
April 2015 | Good | Good | Good | Very Good | 30 | 59.4 |
May 2013 | Good | Very Good | Good | Very Good | 30 | 59.4 |
May 2011 | Good | Very Good | Good | Very Good | 30 | 59.4 |
June 2009 | Good | Very Good | Good | Very Good | 30 | 62.1 |
July 2007 | Poor | Satisfactory | Serious | Poor | 30 | 21.4 |
October 2005 | Poor | Fair | Serious | Poor | 10 | 22.0 |
November 2003 | Poor | Good | Fair | Poor | 30 | 21.4 |
September 2001 | Poor | Good | Fair | Poor | 30 | 21.4 |
July 1999 | Poor | Good | Satisfactory | Poor | 30 | 40.5 |
June 1997 | Fair | Good | Satisfactory | Good | 30 | 59.0 |
January 1995 | Fair | Good | Satisfactory | Satisfactory | 30 | 24.7 |
May 1993 | Fair | Good | Satisfactory | Satisfactory | 30 | 36.6 |
March 1992 | Fair | Good | Satisfactory | Satisfactory | 30 | 36.6 |
May 1991 | Poor | Good | Poor | Serious | 30 | 21.9 |