Share:

COUNTY ROAD over WILLOW CREEK

Map

Coordinates:
+39.60194, -109.56989
39°36'07" N, 109°34'12" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:COUNTY ROAD over WILLOW CREEK
Structure number:047059C
Location:12.5 MI.S.BUCK CYN.RD.JCT
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:36.1 ft. [11.0 m]
Total length:40.0 ft. [12.2 m]
Roadway width between curbs:14.1 ft. [4.3 m]
Deck width edge-to-edge:14.1 ft. [4.3 m]
Owner:County Highway Agency [02]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Corrugated Steel [6]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:13 [as of 2010]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:47.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairFairFairFair1347.5
April 2016FairSatisfactoryFairFair1349.5
April 2014FairSatisfactoryFairFair1357.3
April 2012FairSatisfactoryFairFair1357.3
May 2010FairSatisfactoryFairFair1357.3
September 2007PoorSatisfactoryFairSerious1331.9
July 2006PoorFairPoorSerious1031.0
July 2004PoorFairPoorSerious1031.0
May 2002PoorFairPoorSerious1031.0
May 2000PoorFairPoorSerious1031.0
May 1998PoorFairPoorSerious1031.0
May 1996PoorFairPoorSerious1031.0
April 1994PoorFairSatisfactoryPoor1048.3
March 1992PoorFairSatisfactoryPoor1048.3
August 1990PoorSatisfactorySatisfactoryPoor1049.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.160016000
Substructure
Other Material Abutmentlinear ft.2802800
Deck