LINCOLN AVENUE over OGDEN RIVER
Map
Coordinates:
+41.23439, -111.9757441°14'04" N, 111°58'33" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | LINCOLN AVENUE over OGDEN RIVER |
Structure number: | 057026F |
Location: | 1800 S. LINCOLN AVE.OGDEN |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Collector (Urban) [17] |
Length of largest span: | 68.6 ft. [20.9 m] |
Total length: | 70.9 ft. [21.6 m] |
Roadway width between curbs: | 53.2 ft. [16.2 m] |
Deck width edge-to-edge: | 66.3 ft. [20.2 m] |
Skew angle: | 25° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1965 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,990 [as of 2014] |
Truck traffic: | 4% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 97.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Fair | Good | Good | 4990 | 97.3 |
April 2016 | Fair | Fair | Good | Good | 4990 | 97.3 |
April 2014 | Fair | Fair | Good | Good | 4990 | 97.3 |
April 2012 | Fair | Fair | Good | Good | 4990 | 97.3 |
April 2010 | Fair | Satisfactory | Good | Good | 4990 | 98.3 |
April 2008 | Fair | Satisfactory | Good | Good | 4990 | 98.3 |
July 2006 | Fair | Satisfactory | Good | Satisfactory | 3960 | 98.4 |
June 2004 | Fair | Satisfactory | Good | Satisfactory | 3960 | 98.4 |
April 2002 | Fair | Satisfactory | Good | Satisfactory | 3960 | 98.4 |
April 2000 | Fair | Satisfactory | Good | Satisfactory | 3960 | 93.4 |
April 1998 | Fair | Satisfactory | Good | Satisfactory | 5950 | 93.1 |
May 1996 | Fair | Good | Good | Satisfactory | 5950 | 93.1 |
June 1994 | Fair | Good | Good | Satisfactory | 5915 | 98.1 |
July 1992 | Fair | Good | Good | Satisfactory | 6840 | 97.0 |
September 1990 | Fair | Good | Good | Satisfactory | 6840 | 96.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 490 | 490 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,709 | 2,959 | 1,500 | 250 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 133 | 126 | 0 | 7 | 0 |
Joints |
Assembly with Seal | each | 133 | 133 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 14 | 14 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 222 | 142 | 0 | 80 | 0 |
Other Material Bridge Rail | linear ft. | 222 | 127 | 0 | 95 | 0 |