US-191 (SR-191) over VALLEY CITY WASH
Map
Coordinates:
+38.86394, -109.8078838°51'50" N, 109°48'28" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US-191 (SR-191) over VALLEY CITY WASH |
Structure number: | 0F 426 |
Location: | 5.5 MI.SO.of CRESCENT JCT |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 102.0 ft. [31.1 m] |
Total length: | 105.0 ft. [32.0 m] |
Roadway width between curbs: | 32.5 ft. [9.9 m] |
Deck width edge-to-edge: | 36.1 ft. [11.0 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 1978 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,555 [as of 2014] |
Truck traffic: | 49% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 78.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Good | Good | Satisfactory | 6555 | 78.0 |
September 2015 | Good | Good | Good | Good | 6555 | 78.0 |
September 2013 | Good | Good | Good | Good | 5819 | 73.8 |
September 2011 | Good | Good | Good | Good | 5130 | 78.0 |
August 2009 | Good | Good | Good | Good | 5130 | 78.0 |
October 2007 | Good | Good | Good | Good | 2975 | 78.0 |
October 2005 | Good | Good | Good | Good | 2975 | 77.0 |
October 2003 | Good | Good | Good | Good | 2901 | 77.0 |
September 1999 | Good | Good | Good | Good | 2860 | 72.0 |
September 1997 | Good | Good | Good | Good | 2570 | 72.0 |
November 1995 | Good | Good | Very Good | Good | 2315 | 77.0 |
October 1993 | Good | Good | Very Good | Good | 1875 | 78.9 |
January 1992 | Good | Good | Very Good | Good | 1605 | 80.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 413 | 409 | 4 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 3,741 | 3,716 | 20 | 5 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 83 | 50 | 31 | 2 | 0 |
Bridge Rail |