I-84 (SR-84) WBL over WEBER RIVER
Map
Coordinates:
+41.03573, -111.5096941°02'09" N, 111°30'35" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-84 (SR-84) WBL over WEBER RIVER |
Structure number: | 4F 201 |
Location: | NORTHWEST OF HENEFER |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 60.4 ft. [18.4 m] |
Total length: | 126.0 ft. [38.4 m] |
Roadway width between curbs: | 37.7 ft. [11.5 m] |
Deck width edge-to-edge: | 41.3 ft. [12.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1971 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,985 [as of 2014] |
Truck traffic: | 50% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 85.8 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 6985 | 85.8 |
August 2016 | Fair | Satisfactory | Good | Good | 6985 | 85.8 |
August 2014 | Fair | Satisfactory | Good | Good | 3329 | 93.3 |
August 2012 | Fair | Satisfactory | Good | Good | 3599 | 96.8 |
October 2010 | Fair | Satisfactory | Good | Good | 4505 | 95.8 |
September 2008 | Good | Good | Good | Good | 4505 | 95.8 |
October 2006 | Good | Good | Good | Good | 4210 | 95.8 |
September 2004 | Fair | Satisfactory | Good | Good | 4210 | 95.8 |
August 2002 | Fair | Satisfactory | Good | Good | 4523 | 95.8 |
August 2000 | Fair | Satisfactory | Good | Good | 3663 | 90.8 |
August 1998 | Good | Good | Good | Good | 3663 | 90.8 |
September 1996 | Good | Good | Good | Good | 2762 | 90.9 |
October 1994 | Good | Good | Very Good | Good | 2762 | 95.8 |
December 1992 | Good | Good | Very Good | Good | 2460 | 96.8 |
July 1991 | Good | Good | Very Good | Good | 2200 | 96.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 616 | 596 | 20 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,100 | 4,090 | 190 | 820 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 32 | 27 | 5 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 82 | 58 | 24 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 40 | 35 | 5 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 20 | 20 | 0 | 0 | 0 |
Bridge Rail |
Other Material Bridge Rail | linear ft. | 312 | 0 | 0 | 312 | 0 |