Share:

I-95 (SBL) over CSX RAILROAD

Map

Coordinates:
+37.92433, -77.46268
37°55'28" N, 77°27'46" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-95 (SBL) over CSX RAILROAD
Structure number:000000000004378
Location:2.4M HANON CL-0.9M RTE207
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:51.8 ft. [15.8 m]
Total length:146.0 ft. [44.5 m]
Roadway width between curbs:64.6 ft. [19.7 m]
Deck width edge-to-edge:67.9 ft. [20.7 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:12°
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:49,402 [as of 2014]
Truck traffic:11% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:82.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018FairSatisfactorySatisfactorySatisfactory4940282.9
January 2016FairGoodSatisfactorySatisfactory4940283.0
January 2014FairGoodSatisfactorySatisfactory3250083.0
January 2012FairGoodSatisfactorySatisfactory3250070.9
January 2010FairGoodSatisfactoryFair3250072.0
January 2008FairGoodSatisfactoryFair3250073.0
April 2006FairGoodSatisfactorySatisfactory3250084.0
March 2004FairGoodSatisfactorySatisfactory3250084.0
March 2002FairGoodSatisfactorySatisfactory3250084.0
February 2000FairGoodSatisfactorySatisfactory3250084.0
January 1998FairGoodSatisfactorySatisfactory3250084.0
April 1996FairGoodSatisfactorySatisfactory3500084.0
January 1994FairVery GoodSatisfactorySatisfactory2657084.0
February 1992FairVery GoodSatisfactorySatisfactory2657084.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.568568000
Steel Protective Coatingsq. ft.2,8402,840000
Prestressed Concrete Girder/Beamlinear ft.1,1351,0834570
Deck
Reinforced Concrete Decksq. ft.9,9159,83055300
Substructure
Reinforced Concrete Columneach104600
Reinforced Concrete Pier Walllinear ft.69521502
Reinforced Concrete Abutmentlinear ft.17813825150
Reinforced Concrete Pier Caplinear ft.136973360
Joints
Pourable Jointlinear ft.26221431170
Bearings
Elastomeric Bearingeach4800480
Steel Protective Coatingsq. ft.9696000
Movable Bearingeach1200120
Steel Protective Coatingsq. ft.2424000
Fixed Bearingeach1200120
Steel Protective Coatingsq. ft.2424000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2922623000