HARRY BYRD HWY-WBL over OPEQUON CREEK
Map
Coordinates:
+39.17843, -78.0732839°10'42" N, 78°04'24" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | HARRY BYRD HWY-WBL over OPEQUON CREEK |
Structure number: | 000000000005379 |
Location: | 0.00 CLARK-0.00 FREDERICK |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 60.0 ft. [18.3 m] |
Total length: | 240.2 ft. [73.2 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 42.0 ft. [12.8 m] |
Skew angle: | 19° |
Owner: | State Highway Agency [01] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 4 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 12,887 [as of 2014] |
Truck traffic: | 4% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 84.6 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2017 | Fair | Good | Satisfactory | Fair | 12887 | 84.6 |
August 2015 | Fair | Good | Satisfactory | Fair | 12887 | 84.6 |
August 2013 | Fair | Good | Satisfactory | Fair | 13226 | 84.6 |
August 2011 | Fair | Good | Good | Satisfactory | 13226 | 95.8 |
August 2009 | Fair | Very Good | Very Good | Satisfactory | 13226 | 98.8 |
July 2007 | Fair | Very Good | Very Good | Satisfactory | 16157 | 98.5 |
July 2005 | Good | Very Good | Very Good | Very Good | 12979 | 98.8 |
July 2003 | Good | Very Good | Very Good | Very Good | 12277 | 98.9 |
August 2001 | Fair | Very Good | Fair | Fair | 12000 | 87.7 |
July 1999 | Fair | Fair | Fair | Fair | 8744 | 85.0 |
June 1997 | Fair | Satisfactory | Fair | Fair | 8500 | 86.1 |
May 1995 | Fair | Very Good | Fair | Fair | 4700 | 86.6 |
June 1993 | Fair | Very Good | Fair | Fair | 7350 | 86.4 |
June 1991 | Fair | Good | Fair | Fair | 6980 | 86.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 1,440 | 1,427 | 4 | 9 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 10,080 | 9,772 | 308 | 0 | 0 |
Wearing Surfaces | sq. ft. | 50 | 0 | 0 | 0 | 50 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 42 | 27 | 15 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 88 | 53 | 33 | 2 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 43 | 0 | 40 | 3 | 0 |
Joints |
Compression Joint | linear ft. | 92 | 92 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 24 | 0 | 24 | 0 | 0 |
Fixed Bearing | each | 24 | 0 | 24 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 480 | 480 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 480 | 480 | 0 | 0 | 0 |