SinkingCreekRd/772 over Sinking Creek
Map
Coordinates:
+37.29901, -80.5969037°17'56" N, 80°35'49" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SinkingCreekRd/772 over Sinking Creek |
Structure number: | 000000000008514 |
Location: | 2.30-Rte771;0.45-Rte612 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 22.6 ft. [6.9 m] |
Total length: | 73.2 ft. [22.3 m] |
Roadway width between curbs: | 20.7 ft. [6.3 m] |
Deck width edge-to-edge: | 21.7 ft. [6.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 1967 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 209 [as of 2014] |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 70.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $2,235,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2018 | Fair | Good | Fair | Satisfactory | 209 | 70.0 |
March 2017 | Fair | Good | Fair | Satisfactory | 209 | 70.0 |
March 2016 | Fair | Good | Fair | Satisfactory | 209 | 70.0 |
March 2015 | Fair | Good | Fair | Satisfactory | 209 | 70.0 |
March 2014 | Fair | Good | Fair | Fair | 380 | 66.9 |
March 2012 | Fair | Good | Fair | Fair | 380 | 66.9 |
March 2010 | Fair | Good | Fair | Satisfactory | 380 | 66.9 |
January 2008 | Fair | Good | Satisfactory | Satisfactory | 575 | 78.9 |
January 2006 | Fair | Good | Satisfactory | Satisfactory | 575 | 78.9 |
January 2004 | Fair | Good | Satisfactory | Satisfactory | 575 | 75.9 |
January 2002 | Fair | Good | Satisfactory | Satisfactory | 488 | 75.9 |
January 2000 | Fair | Very Good | Good | Satisfactory | 488 | 75.9 |
February 1998 | Fair | Fair | Good | Satisfactory | 488 | 74.9 |
February 1996 | Fair | Fair | Good | Satisfactory | 488 | 74.9 |
March 1994 | Good | Good | Very Good | Very Good | 374 | 77.9 |
February 1992 | Good | Good | Good | Good | 374 | 77.3 |
February 1990 | Good | Good | Good | Good | 374 | 77.3 |