Share:

EBL ROUTE 0360 over MATTAPONI RIVER

Map

Coordinates:
+37.78652, -77.10408
37°47'11" N, 77°06'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:EBL ROUTE 0360 over MATTAPONI RIVER
Structure number:000000000010593
Location:0.0M K&Q CO-0.0M K.WM. CO
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:129.9 ft. [39.6 m]
Total length:360.9 ft. [110.0 m]
Roadway width between curbs:33.1 ft. [10.1 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: May 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,370 [as of 2014]
Truck traffic:4% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:86.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2018FairFairFairFair537086.0
May 2016FairSatisfactoryFairFair537087.0
May 2014FairSatisfactorySatisfactorySatisfactory557099.0
May 2012FairSatisfactorySatisfactorySatisfactory557097.0
May 2010FairSatisfactoryGoodSatisfactory557097.0
June 2008FairSatisfactoryFairSatisfactory557086.0
June 2006FairGoodFairSatisfactory552387.0
June 2004FairFairFairSatisfactory523086.0
June 2002FairGoodFairSatisfactory493187.0
June 2000FairFairFairSatisfactory482784.0
July 1998FairFairFairSatisfactory482784.0
August 1996FairFairSatisfactorySatisfactory700095.0
June 1994FairFairVery GoodSatisfactory770095.0
July 1993FairSatisfactoryVery GoodSatisfactory374596.0
July 1992FairSatisfactoryVery GoodSatisfactory261796.0
July 1991FairSatisfactoryVery GoodSatisfactory261796.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,8031,546881690
Steel Protective Coatingsq. ft.21,45721,457000
Deck
Reinforced Concrete Decksq. ft.12,66812,2462781440
Wearing Surfacessq. ft.12,66812,533122130
Substructure
Reinforced Concrete Columneach81070
Reinforced Concrete Abutmentlinear ft.1035023300
Reinforced Concrete Pier Caplinear ft.1553291230
Joints
Strip Seal Jointlinear ft.1442311803
Pourable Jointlinear ft.72730035
Bearings
Movable Bearingeach25010150
Steel Protective Coatingsq. ft.1501113900
Fixed Bearingeach2500250
Steel Protective Coatingsq. ft.1501133700
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.722568139150