NBL ROUTE 0095 over POTOMAC CREEK
Map
Coordinates:
+38.37954, -77.4550938°22'46" N, 77°27'18" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | NBL ROUTE 0095 over POTOMAC CREEK |
Structure number: | 000000000018094 |
Location: | 3.4M RTE17-3.5M RTE630 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 47.9 ft. [14.6 m] |
Total length: | 142.1 ft. [43.3 m] |
Roadway width between curbs: | 64.6 ft. [19.7 m] |
Deck width edge-to-edge: | 67.9 ft. [20.7 m] |
Skew angle: | 11° |
Owner: | State Highway Agency [01] |
Year built: | 1963 |
Year reconstructed: | 1987 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 66,862 [as of 2014] |
Truck traffic: | 8% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Countermeasures have been installed to mitigate an existing problem with scour. [7] |
Sufficiency rating: | 100.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Fair | Good | Satisfactory | Satisfactory | 66862 | 100.0 |
October 2016 | Fair | Good | Fair | Fair | 66862 | 89.0 |
October 2014 | Fair | Good | Fair | Fair | 68000 | 86.8 |
October 2012 | Fair | Good | Satisfactory | Satisfactory | 65487 | 97.8 |
October 2010 | Fair | Good | Satisfactory | Satisfactory | 65487 | 98.0 |
October 2008 | Fair | Good | Satisfactory | Satisfactory | 65487 | 98.0 |
October 2006 | Fair | Good | Satisfactory | Satisfactory | 62760 | 98.0 |
October 2004 | Fair | Good | Satisfactory | Satisfactory | 60464 | 90.5 |
October 2002 | Fair | Good | Satisfactory | Satisfactory | 52616 | 90.5 |
October 2000 | Good | Good | Good | Good | 55330 | 90.5 |
November 1998 | Good | Good | Good | Good | 55330 | 90.5 |
November 1996 | Good | Good | Good | Good | 46000 | 90.5 |
November 1994 | Good | Good | Good | Good | 86000 | 90.5 |
December 1992 | Good | Good | Good | Good | 28675 | 97.2 |
October 1990 | Good | Good | Good | Good | 28675 | 97.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,421 | 1,370 | 51 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 9,647 | 9,592 | 51 | 4 | 0 |
Wearing Surfaces | sq. ft. | 9,181 | 6,898 | 2,250 | 33 | 0 |
Substructure |
Reinforced Concrete Column | each | 10 | 6 | 4 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 141 | 53 | 88 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 135 | 90 | 45 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 272 | 204 | 46 | 22 | 0 |
Bearings |
Elastomeric Bearing | each | 60 | 3 | 45 | 9 | 3 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 285 | 234 | 47 | 4 | 0 |