Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | EBL ROUTE 0064 over RTE 154(DURANT RD) & CSX |
Structure number: | 000000000020157 |
Location: | .35 W A C L & 1.05 E ACL |
Purpose: | Carries highway overpass over highway and railroad |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 94.2 ft. [28.7 m] |
Total length: | 253.0 ft. [77.1 m] |
Roadway width between curbs: | 43.6 ft. [13.3 m] |
Deck width edge-to-edge: | 46.9 ft. [14.3 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 4° |
Owner: | State Highway Agency [01] |
Year built: | 1964 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 4 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,972 [as of 2014] |
Truck traffic: | 21% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 93.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 6972 | 93.3 |
November 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 6972 | 89.3 |
November 2013 | Fair | Satisfactory | Good | Satisfactory | 6736 | 90.3 |
November 2011 | Good | Good | Good | Good | 6736 | 90.3 |
November 2009 | Good | Good | Good | Good | 6736 | 92.3 |
October 2007 | Good | Good | Good | Good | 6538 | 92.4 |
September 2005 | Good | Good | Good | Good | 7714 | 93.0 |
September 2003 | Good | Good | Good | Good | 7335 | 93.0 |
October 2001 | Good | Good | Good | Good | 7464 | 93.0 |
October 1999 | Fair | Good | Fair | Good | 11475 | 82.0 |
September 1997 | Fair | Good | Fair | Good | 11475 | 82.0 |
October 1995 | Fair | Good | Fair | Good | 11475 | 82.0 |
September 1993 | Fair | Good | Fair | Fair | 11475 | 81.2 |
September 1991 | Fair | Good | Satisfactory | Fair | 11475 | 81.2 |
September 1989 | Fair | Good | Satisfactory | Fair | 11475 | 79.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,771 | 1,656 | 115 | 0 | 0 |
Steel Protective Coating | sq. ft. | 19,481 | 18,249 | 0 | 1,232 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 11,868 | 10,194 | 1,669 | 5 | 0 |
Wearing Surfaces | sq. ft. | 11,038 | 10,717 | 318 | 3 | 0 |
Substructure |
Reinforced Concrete Column | each | 9 | 4 | 5 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 116 | 59 | 52 | 4 | 1 |
Reinforced Concrete Pier Cap | linear ft. | 144 | 76 | 47 | 21 | 0 |
Joints |
Compression Joint | linear ft. | 230 | 0 | 230 | 0 | 0 |
Bearings |
Movable Bearing | each | 28 | 0 | 28 | 0 | 0 |
Steel Protective Coating | sq. ft. | 112 | 75 | 0 | 37 | 0 |
Fixed Bearing | each | 28 | 0 | 27 | 1 | 0 |
Steel Protective Coating | sq. ft. | 112 | 75 | 0 | 37 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 506 | 505 | 0 | 1 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 506 | 313 | 193 | 0 | 0 |