Odd Fellows Road over Rt 29 BP & Fishing Creek
Map
Coordinates:
+37.38606, -79.1673637°23'10" N, 79°10'02" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Odd Fellows Road over Rt 29 BP & Fishing Creek |
Structure number: | 000000000020498 |
Location: | 000029 EXP 0029128 |
Purpose: | Carries highway over highway and waterway |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 89.9 ft. [27.4 m] |
Total length: | 237.9 ft. [72.5 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 33.1 ft. [10.1 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1961 |
Year reconstructed: | 1992 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,466 [as of 2014] |
Truck traffic: | 12% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 80.1 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Good | Good | Satisfactory | 7466 | 80.1 |
May 2016 | Fair | Good | Good | Satisfactory | 7466 | 80.1 |
May 2014 | Good | Good | Good | Good | 7400 | 81.1 |
May 2012 | Good | Good | Good | Good | 8479 | 82.0 |
May 2010 | Fair | Good | Good | Satisfactory | 8479 | 81.0 |
June 2008 | Fair | Good | Good | Satisfactory | 8479 | 81.0 |
May 2006 | Good | Good | Very Good | Good | 8479 | 82.0 |
May 2004 | Good | Good | Very Good | Good | 8479 | 82.0 |
May 2002 | Good | Good | Very Good | Good | 8479 | 82.0 |
May 2000 | Good | Very Good | Very Good | Good | 8479 | 82.0 |
May 1998 | Good | Very Good | Very Good | Good | 8479 | 82.0 |
June 1996 | Good | Very Good | Very Good | Good | 8479 | 82.0 |
May 1994 | Good | Very Good | Very Good | Very Good | 8479 | 82.2 |
May 1992 | Good | Excellent | Excellent | Excellent | 11434 | 81.9 |
January 1991 | Poor | Poor | Fair | Poor | 11269 | 40.3 |