Share:

LONDON BOULEVARD over N&P RAILWAY & VA AVE

Map

Coordinates:
+36.83760, -76.33108
36°50'15" N, 76°19'52" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:LONDON BOULEVARD over N&P RAILWAY & VA AVE
Structure number:000000000021200
Location:1.57TUNNL ENT/0.84 TO 17
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:81.0 ft. [24.7 m]
Total length:420.0 ft. [128.0 m]
Roadway width between curbs:84.0 ft. [25.6 m]
Deck width edge-to-edge:96.8 ft. [29.5 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Owner:City or Municipal Highway Agency [04]
Year built:1971
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:33,783 [as of 2014]
Truck traffic:2% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:88.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$2,927,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2018FairGoodSatisfactoryGood3378388.9
March 2016FairGoodSatisfactoryVery Good3378388.9
May 2015FairGoodSatisfactoryVery Good3378386.9
May 2013FairGoodSatisfactoryVery Good2697087.6
May 2011FairGoodSatisfactoryVery Good2697087.6
May 2009FairGoodSatisfactoryVery Good2697087.5
July 2007FairGoodSatisfactoryVery Good2697087.5
August 2005FairGoodFairVery Good2697076.1
July 2003FairFairFairFair2697075.1
June 2001FairSatisfactoryFairSatisfactory2697076.1
January 2000FairSatisfactoryFairSatisfactory2697076.1
January 1998FairGoodSatisfactoryGood2697090.5
October 1995GoodGoodGoodGood2697091.1
January 1994GoodGoodGoodGood2697095.2
August 1991GoodGoodGoodGood2697091.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.5,8525,592200600
Steel Protective Coatingsq. ft.52,18051,6004001800
Deck
Reinforced Concrete Decksq. ft.29,53826,4663,038340
Wearing Surfacessq. ft.31,35631,351005
Substructure
Reinforced Concrete Columneach42202200
Reinforced Concrete Abutmentlinear ft.2071862100
Reinforced Concrete Pier Caplinear ft.68822446130
Joints
Pourable Jointlinear ft.870392385930
Bearings
Elastomeric Bearingeach112011200
Fixed Bearingeach112011200
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8367815500