Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROYWEBEXPRSWY/220 over WALNUT AV & JEFFRSN ST
Structure number:000000000021717
Location:0.50-RT24; 2.30-ROANOKE-C
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:133.9 ft. [40.8 m]
Total length:369.1 ft. [112.5 m]
Roadway width between curbs:94.2 ft. [28.7 m]
Deck width edge-to-edge:100.1 ft. [30.5 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:35°
Owner:State Highway Agency [01]
Year built:1973
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:66,000 [as of 2017]
Truck traffic:13% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:85.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2018FairSatisfactoryFairFair6600085.0
August 2017FairSatisfactoryFairFair7074185.0
August 2016FairSatisfactoryFairFair7074185.0
August 2015FairSatisfactoryFairFair7074185.0
August 2014FairSatisfactoryFairFair5794785.0
August 2013FairSatisfactoryFairFair5794785.0
August 2012FairSatisfactoryFairFair5794785.0
August 2011FairSatisfactoryFairFair5794785.0
August 2010FairSatisfactoryFairFair5794785.0
August 2009FairSatisfactoryFairFair5794785.0
August 2008FairSatisfactoryFairFair6307985.0
August 2007FairSatisfactoryFairFair6508185.0
September 2006FairSatisfactoryFairFair6470085.0
August 2005FairSatisfactoryFairFair6478285.0
August 2004FairSatisfactoryFairFair6251388.0
July 2003FairSatisfactoryFairFair6647488.0
June 2001FairGoodFairFair6128388.0
July 2000FairGoodFairFair5200086.0
June 1999FairGoodFairFair5200086.0
June 1997FairGoodFairFair6400086.0
April 1995FairSatisfactoryFairFair2816586.0
April 1994FairSatisfactoryFairFair2816586.0
April 1992GoodVery GoodVery GoodVery Good2816597.0
January 1990GoodVery GoodVery GoodVery Good2816595.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.4,4644,456170
Steel Protective Coatingsq. ft.40,40836,1884,155065
Deck
Reinforced Concrete Decksq. ft.36,93536,742180130
Wearing Surfacessq. ft.35,00234,9099120
Substructure
Reinforced Concrete Columneach3535000
Reinforced Concrete Abutmentlinear ft.3472846120
Reinforced Concrete Pier Caplinear ft.650512125130
Joints
Pourable Jointlinear ft.940009400
Bearings
Movable Bearingeach9000900
Steel Protective Coatingsq. ft.356356000
Fixed Bearingeach6500650
Steel Protective Coatingsq. ft.356035600
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.740740000
Reinforced Concrete Bridge Raillinear ft.1,1071,105200