Share:

ROUTE 0011 over APPERSN DR O ROANOKE RV

Map

Coordinates:
+37.26768, -80.02655
37°16'04" N, 80°01'36" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 0011 over APPERSN DR O ROANOKE RV
Structure number:000000000021770
Location:0028419 0085419
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:75.1 ft. [22.9 m]
Total length:199.2 ft. [60.7 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:51.8 ft. [15.8 m]
Owner:City or Municipal Highway Agency [04]
Year built:1942
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,476 [as of 2014]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:60.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,500,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairFairFairSatisfactory1347660.0
August 2016FairFairFairSatisfactory1347660.0
April 2016FairFairFairSatisfactory1347660.0
April 2014FairSatisfactoryFairSatisfactory1847359.9
September 2013FairSatisfactoryFairSatisfactory1847359.9
April 2012FairSatisfactoryFairSatisfactory1847359.9
April 2011PoorVery GoodPoorSatisfactory1847335.1
April 2010PoorVery GoodPoorSatisfactory1847335.1
March 2009PoorVery GoodPoorSatisfactory1847335.1
March 2008PoorVery GoodPoorSatisfactory1847335.1
March 2007PoorVery GoodPoorFair1847335.1
March 2006PoorVery GoodPoorFair1847335.1
April 2005PoorVery GoodPoorFair1847335.1
March 2004PoorVery GoodPoorFair1847335.1
June 2003PoorVery GoodPoorFair1847335.1
March 2002PoorVery GoodPoorFair1847335.1
March 2001PoorVery GoodPoorFair1847335.1
January 1999FairGoodSatisfactoryGood1847368.0
November 1996FairGoodSatisfactoryGood1847368.0
December 1995FairGoodGoodSatisfactory1847364.7
February 1995FairGoodSatisfactoryGood1847367.7
October 1992FairGoodSatisfactoryGood1847367.7
October 1990FairGoodSatisfactoryGood1847367.7

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,593001,5858
Steel Protective Coatingsq. ft.9,55202,3882,3884,776
Deck
Reinforced Concrete Decksq. ft.10,3244,6485,67600
Wearing Surfacessq. ft.7,9727,254286900
Substructure
Reinforced Concrete Pier Walllinear ft.8775840
Reinforced Concrete Abutmentlinear ft.116229400
Reinforced Concrete Pier Caplinear ft.8886200
Joints
Compression Jointlinear ft.10496080