Share:

ROUTE 0419 over ELECTRIC RD O NS RWY @

Map

Coordinates:
+37.27269, -80.03751
37°16'22" N, 80°02'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:ROUTE 0419 over ELECTRIC RD O NS RWY @
Structure number:000000000021777
Location:001111 015011 & 460
Purpose:Carries highway and pedestrian walkway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:63.0 ft. [19.2 m]
Total length:273.0 ft. [83.2 m]
Roadway width between curbs:62.0 ft. [18.9 m]
Deck width edge-to-edge:74.2 ft. [22.6 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:18°
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 13.5 / HS 15 [3]
Number of main spans:5
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:24,084 [as of 2014]
Truck traffic:1% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:79.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairFairFairFair2408479.3
June 2016FairFairFairFair2408479.3
October 2014FairFairFairFair3018777.7
October 2012FairFairFairFair3018777.7
October 2010FairFairFairFair3018777.7
October 2008FairFairFairFair3018777.7
October 2006FairFairFairFair3018777.7
February 2005FairFairFairFair3018777.7
November 2002FairFairFairFair3018769.2
February 2001FairFairFairFair3018767.2
December 1998FairGoodSatisfactoryGood3018784.7
January 1997FairGoodSatisfactoryGood3018782.7
February 1995FairGoodSatisfactoryGood3018783.1
October 1992FairGoodSatisfactoryGood3018783.1
October 1990FairGoodSatisfactoryGood3018783.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.3,7943,7790150
Steel Protective Coatingsq. ft.27,32827,11800210
Deck
Reinforced Concrete Decksq. ft.20,24115,8214,3171030
Wearing Surfacessq. ft.15,01714,18483003
Substructure
Reinforced Concrete Columneach2471340
Reinforced Concrete Pier Walllinear ft.72442170
Reinforced Concrete Abutmentlinear ft.1961523860
Reinforced Concrete Pier Caplinear ft.336136188120
Joints
Compression Jointlinear ft.5054650400
Bearings
Movable Bearingeach7000700
Steel Protective Coatingsq. ft.21010503075
Fixed Bearingeach70350350
Steel Protective Coatingsq. ft.21010503075
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.546537081
Reinforced Concrete Bridge Raillinear ft.546054600