Share:

DUMFRIES ROAD over COCKRELL BRANCH

Map

Coordinates:
+38.73321, -77.47424
38°43'60" N, 77°28'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:DUMFRIES ROAD over COCKRELL BRANCH
Structure number:000000000024159
Location:00.01 MI. S. OF HASTINGS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:4.9 ft. [1.5 m]
Total length:24.9 ft. [7.6 m]
Owner:City or Municipal Highway Agency [04]
Year built:1985
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:8,759 [as of 2014]
Truck traffic:1% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:82.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2017Good7 out of 10875982.5
August 2015Good7 out of 10875982.5
August 2013Good8 out of 101976079.4
December 2011Good8 out of 101976079.4
December 2009Good8 out of 101976079.4
December 2007Good8 out of 101976073.8
November 2005Good8 out of 101976073.8
June 2003Good8 out of 101976070.8
June 2001Good8 out of 101976073.8
March 1999Good8 out of 101976073.8
March 1997Good8 out of 101976073.8
April 1995Good9 out of 101976071.2