LIBERIA AVE. over NS RAILWAY
Map
Coordinates:
+38.75732, -77.4529738°45'26" N, 77°27'11" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | LIBERIA AVE. over NS RAILWAY |
Structure number: | 000000000024735 |
Location: | 00.45FR28/00.55TO689 |
Purpose: | Carries highway and pedestrian walkway over railroad |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 77.1 ft. [23.5 m] |
Total length: | 77.1 ft. [23.5 m] |
Roadway width between curbs: | 55.1 ft. [16.8 m] |
Deck width edge-to-edge: | 89.2 ft. [27.2 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Skew angle: | 1° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1996 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 40,403 [as of 2014] |
Truck traffic: | 2% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 78.3 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $3,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Good | Good | Good | Good | 40403 | 78.3 |
October 2015 | Good | Good | Very Good | Very Good | 40403 | 78.3 |
October 2013 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
November 2011 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
September 2009 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
July 2007 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
November 2005 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
March 2004 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
January 2002 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
April 2000 | Good | Excellent | Excellent | Very Good | 29774 | 79.5 |
August 1997 | Good | Excellent | Excellent | Excellent | 10370 | 81.8 |