Chincoteague Road over Queens Sound
Map
Coordinates:
+37.93508, -75.4188937°56'06" N, 75°25'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Chincoteague Road over Queens Sound |
Structure number: | 000000000025297 |
Location: | 8.25 fr 13/2.20 to Chinco |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 68.9 ft. [21.0 m] |
Total length: | 1141.1 ft. [347.8 m] |
Roadway width between curbs: | 40.7 ft. [12.4 m] |
Deck width edge-to-edge: | 44.0 ft. [13.4 m] |
Owner: | State Highway Agency [01] |
Year built: | 1997 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 17 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 8,137 [as of 2014] |
Truck traffic: | 2% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 68.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Satisfactory | Good | Fair | 8137 | 68.0 |
June 2015 | Fair | Satisfactory | Good | Satisfactory | 8137 | 79.0 |
June 2013 | Fair | Satisfactory | Very Good | Satisfactory | 6518 | 79.0 |
June 2011 | Fair | Satisfactory | Very Good | Satisfactory | 6518 | 79.0 |
June 2009 | Fair | Satisfactory | Very Good | Satisfactory | 6518 | 79.0 |
July 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 7249 | 79.0 |
June 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 8923 | 79.0 |
July 2003 | Fair | Fair | Very Good | Satisfactory | 5875 | 78.0 |
June 2002 | Fair | Fair | Very Good | Satisfactory | 6187 | 78.0 |
April 2000 | Fair | Fair | Very Good | Satisfactory | 5658 | 78.0 |
April 1998 | Good | Very Good | Very Good | Very Good | 5658 | 79.0 |