Grayson Parkway over NEW RIVER
Map
Coordinates:
+36.61346, -81.0488736°36'48" N, 81°02'56" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Grayson Parkway over NEW RIVER |
Structure number: | 000000000025447 |
Location: | 3.58 FR 274; 1.90 TO 636 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 128.0 ft. [39.0 m] |
Total length: | 1375.7 ft. [419.3 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 43.3 ft. [13.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 1999 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 11 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,285 [as of 2014] |
Truck traffic: | 3% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 91.1 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Satisfactory | Good | Good | 2285 | 91.1 |
April 2015 | Fair | Satisfactory | Good | Good | 2285 | 91.1 |
April 2013 | Fair | Satisfactory | Good | Good | 2518 | 90.2 |
April 2011 | Fair | Satisfactory | Good | Good | 2518 | 90.2 |
July 2009 | Fair | Satisfactory | Very Good | Good | 2518 | 90.2 |
July 2007 | Fair | Satisfactory | Very Good | Good | 2723 | 89.5 |
July 2005 | Fair | Satisfactory | Very Good | Good | 2523 | 90.2 |
September 2003 | Fair | Satisfactory | Very Good | Good | 2519 | 90.2 |
July 2001 | Fair | Satisfactory | Excellent | Satisfactory | 2368 | 88.8 |
July 1999 | Fair | Satisfactory | Excellent | Satisfactory | 4000 | 82.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 9,386 | 9,160 | 226 | 0 | 0 |
Steel Protective Coating | sq. ft. | 123,275 | 103,808 | 19,240 | 225 | 2 |
Deck |
Reinforced Concrete Deck | sq. ft. | 59,604 | 36,744 | 22,860 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 10 | 0 | 10 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 161 | 117 | 40 | 4 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 448 | 373 | 75 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 43 | 0 | 43 | 0 | 0 |
Assembly without Seal Joint | linear ft. | 129 | 129 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 258 | 64 | 0 | 0 | 194 |
Bearings |
Movable Bearing | each | 55 | 50 | 5 | 0 | 0 |
Steel Protective Coating | sq. ft. | 330 | 300 | 0 | 30 | 0 |
Fixed Bearing | each | 15 | 15 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 90 | 90 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 2,855 | 1,475 | 1,380 | 0 | 0 |