US 101 over CALAWAH RIVER
Map
Coordinates:
+47.95961, -124.3927547°57'35" N, 124°23'34" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 101 over CALAWAH RIVER |
Structure number: | 0002396A0000000 |
Location: | 7.8 N JEFFERSON CO |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 170.0 ft. [51.8 m] |
Total length: | 264.1 ft. [80.5 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 29.9 ft. [9.1 m] |
Vertical clearance above deck: | 14.8 ft. [4.5 m] |
Owner: | State Highway Agency [01] |
Year built: | 1938 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: March 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 5,529 [as of 2012] |
Truck traffic: | 15% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 45.2 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $3,590,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
March 2017 | Fair | Satisfactory | Satisfactory | Satisfactory | 5529 | 45.2 |
March 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 5529 | 44.9 |
March 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 6065 | 42.8 |
March 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 6065 | 42.8 |
April 2009 | Fair | Satisfactory | Fair | Satisfactory | 5907 | 30.8 |
May 2007 | Fair | Satisfactory | Fair | Satisfactory | 8558 | 30.8 |
May 2005 | Fair | Satisfactory | Fair | Satisfactory | 8558 | 30.8 |
August 2003 | Fair | Satisfactory | Fair | Satisfactory | 8558 | 30.8 |
August 2001 | Fair | Satisfactory | Fair | Satisfactory | 8558 | 35.9 |
October 1999 | Fair | Satisfactory | Fair | Good | 8474 | 35.9 |
April 1997 | Fair | Satisfactory | Fair | Good | 8474 | 32.5 |
April 1995 | Fair | Satisfactory | Fair | Good | 8474 | 32.5 |
February 1993 | Fair | Satisfactory | Fair | Good | 5400 | 32.5 |
October 1990 | Fair | Good | Satisfactory | Good | 5400 | 42.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 376 | 375 | 0 | 1 | 0 |
Steel Stringer | linear ft. | 850 | 830 | 0 | 20 | 0 |
Steel Protective Coating | sq. ft. | 45,271 | 24,011 | 0 | 18,981 | 2,279 |
Deck |
Reinforced Concrete Deck | sq. ft. | 6,336 | 6,310 | 20 | 0 | 6 |
Wearing Surfaces | sq. ft. | 6,336 | 0 | 6,336 | 0 | 0 |
Superstructure |
Steel Truss | linear ft. | 340 | 130 | 0 | 210 | 0 |
Steel Protective Coating | sq. ft. | 181,085 | 96,047 | 0 | 75,926 | 9,112 |
Steel Floor Beam | linear ft. | 228 | 203 | 0 | 25 | 0 |
Steel Protective Coating | sq. ft. | 12,143 | 6,440 | 0 | 5,091 | 612 |
Steel Gusset Plate | each | 32 | 32 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 8 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 51 | 51 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 51 | 51 | 0 | 0 | 0 |
Joints |
Open Joint | linear ft. | 216 | 0 | 216 | 0 | 0 |
Assembly without Seal Joint | linear ft. | 48 | 0 | 0 | 24 | 24 |
Bearings |
Movable Bearing | each | 2 | 2 | 0 | 0 | 0 |
Fixed Bearing | each | 2 | 0 | 0 | 2 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 528 | 528 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 94 | 79 | 0 | 15 | 0 |