US 395 over 4TH AVE
Map
Coordinates:
+46.20597, -119.1588946°12'21" N, 119°09'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 395 over 4TH AVE |
Structure number: | 0005741A0000000 |
Location: | 3.6 N JCT I-82 |
Purpose: | Carries highway and pedestrian walkway over highway |
Route classification: | Other Principal Arterial (Urban) [14] |
Length of largest span: | 46.9 ft. [14.3 m] |
Total length: | 119.1 ft. [36.3 m] |
Roadway width between curbs: | 65.9 ft. [20.1 m] |
Deck width edge-to-edge: | 83.0 ft. [25.3 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1958 |
Year reconstructed: | 1985 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: February 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 28,749 [as of 2016] |
Truck traffic: | 11% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 69.1 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $3,332,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2018 | Fair | Satisfactory | Fair | Satisfactory | 28749 | 69.1 |
February 2016 | Fair | Satisfactory | Fair | Satisfactory | 26071 | 73.1 |
February 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 26071 | 85.2 |
February 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 26502 | 85.1 |
February 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 24888 | 85.5 |
February 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 25287 | 86.4 |
March 2006 | Fair | Satisfactory | Satisfactory | Satisfactory | 20423 | 87.6 |
June 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 20423 | 84.5 |
April 2002 | Fair | Satisfactory | Satisfactory | Satisfactory | 20423 | 84.5 |
May 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 20423 | 84.5 |
April 1998 | Good | Good | Good | Good | 20423 | 83.5 |
May 1996 | Good | Good | Good | Good | 20423 | 89.2 |
November 1994 | Good | Good | Good | Good | 20423 | 89.2 |
April 1992 | Good | Good | Good | Good | 14850 | 92.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Deck |
Reinforced Concrete Top Flange | sq. ft. | 9,758 | 9,758 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 7,914 | 0 | 7,914 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 20 | 20 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 166 | 162 | 0 | 4 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 162 | 158 | 0 | 4 | 0 |
Joints |
Pourable Joint | linear ft. | 132 | 0 | 0 | 0 | 132 |
Bearings |
Elastomeric Bearing | each | 4 | 2 | 0 | 2 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 238 | 238 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 238 | 238 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 9,758 | 9,590 | 0 | 168 | 0 |