Share:

I-5 over PUYALLUP R/RR/SR 167

This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.

Map

Coordinates:
+47.24045, -122.40103
47°14'26" N, 122°24'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-5 over PUYALLUP R/RR/SR 167
Structure number:0006613A0000000
Location:0.2 N JCT SR 167
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:104.0 ft. [31.7 m]
Total length:1470.2 ft. [448.1 m]
Roadway width between curbs:57.1 ft. [17.4 m]
Deck width edge-to-edge:62.7 ft. [19.1 m]
Vertical clearance below bridge:36.1 ft. [11.0 m]
Skew angle:49°
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:16
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:80,156 [as of 2012]
Truck traffic:9% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:88.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016FairGoodSatisfactorySatisfactory8015688.3
August 2014FairGoodSatisfactorySatisfactory8015688.3
August 2012FairGoodGoodSatisfactory8266888.1
August 2010FairGoodSatisfactorySatisfactory8850087.5
August 2008FairGoodSatisfactorySatisfactory9417387.0
August 2006FairGoodSatisfactorySatisfactory9971486.4
November 2004FairGoodSatisfactorySatisfactory9971486.4
September 2002FairGoodSatisfactoryGood9971486.4
November 2000FairGoodSatisfactoryGood7442288.9
November 1998FairGoodSatisfactoryGood7442288.9
December 1996FairGoodSatisfactoryGood7442288.9
June 1994PoorPoorSatisfactoryGood7442284.9
November 1992FairSatisfactorySatisfactoryGood7170490.5
October 1990PoorPoorGoodGood4823589.2