I-182 over NP RY
Map
Coordinates:
+46.25008, -119.0937546°15'00" N, 119°05'38" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-182 over NP RY |
Structure number: | 0008422D0000000 |
Location: | 7.9 E BENTON CO |
Purpose: | Carries highway over railroad |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 128.0 ft. [39.0 m] |
Total length: | 456.1 ft. [139.0 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 41.3 ft. [12.6 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1968 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 4 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 19,958 [as of 2012] |
Truck traffic: | 9% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 82.8 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $9,850,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Good | Good | Satisfactory | 19958 | 82.8 |
April 2015 | Fair | Good | Good | Satisfactory | 19958 | 82.5 |
April 2013 | Fair | Good | Good | Satisfactory | 19877 | 81.5 |
April 2011 | Fair | Good | Good | Satisfactory | 19877 | 81.5 |
April 2009 | Fair | Good | Good | Satisfactory | 20173 | 81.5 |
March 2007 | Fair | Good | Good | Satisfactory | 16000 | 88.4 |
March 2005 | Fair | Good | Good | Satisfactory | 16000 | 87.4 |
April 2003 | Fair | Good | Good | Satisfactory | 16000 | 87.4 |
June 2001 | Fair | Good | Good | Satisfactory | 9986 | 90.0 |
September 1999 | Fair | Good | Good | Satisfactory | 9986 | 90.0 |
June 1997 | Fair | Good | Good | Satisfactory | 9986 | 90.0 |
July 1995 | Fair | Satisfactory | Good | Satisfactory | 9986 | 90.2 |
June 1993 | Fair | Satisfactory | Good | Satisfactory | 8950 | 90.3 |
August 1990 | Poor | Serious | Good | Good | 5600 | 86.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,824 | 1,824 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24,310 | 16,260 | 0 | 8,000 | 50 |
Deck |
Reinforced Concrete Deck | sq. ft. | 17,328 | 17,322 | 0 | 0 | 6 |
Wearing Surfaces | sq. ft. | 17,328 | 0 | 17,328 | 0 | 0 |
Substructure |
Reinforced Concrete Pier Wall | linear ft. | 78 | 78 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 102 | 100 | 2 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 114 | 114 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 82 | 0 | 82 | 0 | 0 |
Pourable Joint | linear ft. | 153 | 0 | 0 | 0 | 153 |
Bearings |
Movable Bearing | each | 8 | 8 | 0 | 0 | 0 |
Fixed Bearing | each | 12 | 12 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 912 | 912 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 912 | 912 | 0 | 0 | 0 |