SR509 over THEA FOSS WATRWAY & D ST
Map
Coordinates:
+47.24333, -122.4337847°14'36" N, 122°26'02" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR509 over THEA FOSS WATRWAY & D ST |
Structure number: | 0014507A0000000 |
Location: | 0.1 N JCT I-705 |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 350.1 ft. [106.7 m] |
Total length: | 992.2 ft. [302.4 m] |
Roadway width between curbs: | 71.9 ft. [21.9 m] |
Deck width edge-to-edge: | 94.8 ft. [28.9 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1996 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 22.5 / HS 25 [9] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stayed girder [14] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 37,062 [as of 2016] |
Truck traffic: | 6% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.5 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $29,363,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Satisfactory | Satisfactory | Good | 37062 | 88.5 |
September 2015 | Fair | Satisfactory | Satisfactory | Good | 34897 | 88.5 |
September 2013 | Fair | Satisfactory | Satisfactory | Good | 34897 | 91.7 |
September 2011 | Fair | Satisfactory | Satisfactory | Very Good | 32013 | 92.0 |
September 2009 | Fair | Satisfactory | Satisfactory | Very Good | 35584 | 91.7 |
November 2007 | Fair | Satisfactory | Satisfactory | Very Good | 35478 | 91.7 |
October 2005 | Fair | Satisfactory | Satisfactory | Very Good | 24000 | 92.8 |
November 2003 | Fair | Satisfactory | Satisfactory | Very Good | 17000 | 93.4 |
November 2002 | Fair | Satisfactory | Satisfactory | Very Good | 17000 | 93.4 |
October 2001 | Fair | Satisfactory | Satisfactory | Very Good | 17000 | 93.4 |
April 2000 | Fair | Satisfactory | Satisfactory | Very Good | 17000 | 93.4 |
December 1999 | Good | Good | Good | Very Good | 17000 | 91.4 |
June 1998 | Good | Good | Good | Very Good | 17000 | 91.4 |
November 1997 | Good | Good | Good | Very Good | 17000 | 91.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 310 | 278 | 0 | 32 | 0 |
Prestressed Concrete Girder/Beam | linear ft. | 1,338 | 1,308 | 0 | 30 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 97,671 | 97,670 | 0 | 0 | 1 |
Superstructure |
Steel Main Cable | linear ft. | 44 | 44 | 0 | 0 | 0 |
Prestressed Concrete Floor Beam | linear ft. | 3,720 | 3,720 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 8 | 0 | 0 | 0 |
Reinforced Concrete Pile | each | 4 | 4 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 186 | 0 | 186 | 0 | 0 |
Assembly with Seal | each | 111 | 0 | 111 | 0 | 0 |
Bearings |
Movable Bearing | each | 2 | 2 | 0 | 0 | 0 |
Enclosed/Concealed Bearing | each | 2 | 2 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 2,261 | 2,259 | 0 | 2 | 0 |