Share:

FIFTH AVENUE over SALMON CREEK

Map

Coordinates:
+48.36258, -119.58739
48°21'45" N, 119°35'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FIFTH AVENUE over SALMON CREEK
Structure number:085265000000000
Location:.07 S OF TYEE ST
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:37.1 ft. [11.3 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:38.1 ft. [11.6 m]
Owner:City or Municipal Highway Agency [04]
Year built:1970
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Prestressed concrete [5]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Other [9]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2099

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:260 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:75.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,459,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2099FairGoodFairSatisfactory26075.2
October 2017FairGoodSatisfactoryFair26075.2
October 2015FairGoodGoodFair26061.5
October 2013FairGoodGoodFair25061.5
November 2011FairGoodGoodFair25061.5
December 2009FairGoodGoodFair20061.5
February 2008FairGoodGoodFair20061.5
January 2006FairGoodGoodFair20061.5
February 2004FairGoodGoodFair20061.5
March 2002FairGoodGoodFair20064.8
April 1998FairGoodGoodFair20064.8
September 1996FairGoodGoodSatisfactory20073.2
May 1994GoodGoodGoodGood20092.0
September 1992GoodGoodGoodGood20092.0