COUNTY ROUTE 25 over MUDDY CREEK
Map
Coordinates:
+37.79246, -80.6208237°47'33" N, 80°37'15" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COUNTY ROUTE 25 over MUDDY CREEK |
Structure number: | 00000000013A072 |
Location: | 0.14 M. South of CR 25/4 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 67.3 ft. [20.5 m] |
Total length: | 71.9 ft. [21.9 m] |
Roadway width between curbs: | 15.1 ft. [4.6 m] |
Deck width edge-to-edge: | 16.1 ft. [4.9 m] |
Owner: | State Highway Agency [01] |
Year built: | 1973 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Girder and floorbeam system [03] |
Deck type: | Wood or Timber [8] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 155 [as of 2016] |
Truck traffic: | 10% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Poor [4 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 43.0 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $927,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Poor | Satisfactory | Poor | Fair | 155 | 43.0 |
June 2016 | Poor | Good | Poor | Fair | 151 | 54.4 |
June 2014 | Poor | Poor | Fair | Fair | 150 | 67.5 |
June 2012 | Fair | Satisfactory | Fair | Fair | 150 | 39.8 |
June 2010 | Fair | Good | Fair | Fair | 150 | 70.5 |
June 2008 | Fair | Good | Fair | Fair | 140 | 70.5 |
June 2006 | Fair | Good | Fair | Fair | 150 | 69.1 |
May 2004 | Fair | Good | Fair | Fair | 150 | 66.4 |
June 2002 | Fair | Good | Fair | Fair | 150 | 64.2 |
June 2000 | Fair | Good | Fair | Fair | 150 | 70.5 |
June 1998 | Fair | Very Good | Fair | Fair | 150 | 70.5 |
June 1996 | Fair | Very Good | Fair | Fair | 150 | 70.5 |
June 1994 | Fair | Very Good | Fair | Fair | 150 | 70.9 |
June 1992 | Poor | Poor | Fair | Satisfactory | 150 | 67.1 |
June 1990 | Fair | Satisfactory | Satisfactory | Fair | 150 | 70.1 |