I-64 EBL over US 60
Map
Coordinates:
+37.84567, -80.4796337°50'44" N, 80°28'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-64 EBL over US 60 |
Structure number: | 00000000013A146 |
Location: | 3.52 Miles W. of US 219 |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 49.9 ft. [15.2 m] |
Total length: | 124.0 ft. [37.8 m] |
Roadway width between curbs: | 40.4 ft. [12.3 m] |
Deck width edge-to-edge: | 44.6 ft. [13.6 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1968 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel continuous [4] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: November 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 6,495 [as of 2015] |
Truck traffic: | 22% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 86.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2018 | Fair | Satisfactory | Fair | Satisfactory | 6495 | 86.0 |
November 2016 | Fair | Satisfactory | Fair | Satisfactory | 6495 | 86.0 |
October 2014 | Fair | Satisfactory | Fair | Satisfactory | 7776 | 86.0 |
November 2012 | Good | Good | Good | Good | 8750 | 97.0 |
November 2010 | Good | Good | Good | Good | 8750 | 95.2 |
October 2008 | Fair | Good | Satisfactory | Good | 9900 | 94.8 |
October 2006 | Fair | Good | Satisfactory | Good | 9000 | 94.9 |
October 2004 | Fair | Good | Satisfactory | Good | 7750 | 94.5 |
October 2002 | Fair | Good | Satisfactory | Good | 8000 | 93.2 |
October 2000 | Fair | Good | Satisfactory | Good | 6750 | 93.3 |
October 1998 | Fair | Good | Satisfactory | Good | 6250 | 93.4 |
October 1996 | Good | Very Good | Good | Very Good | 6250 | 95.4 |
October 1994 | Fair | Satisfactory | Good | Satisfactory | 6000 | 93.5 |
October 1992 | Good | Good | Good | Good | 6500 | 93.5 |
October 1990 | Good | Good | Good | Good | 5250 | 93.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 720 | 474 | 246 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,402 | 5,282 | 120 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,400 | 5,376 | 0 | 24 | 0 |
Wearing Surfaces | sq. ft. | 5,400 | 5,346 | 54 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 158 | 91 | 49 | 18 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 88 | 88 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 90 | 59 | 31 | 0 | 0 |
Bearings |
Movable Bearing | each | 12 | 0 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 4 | 2 | 2 | 0 | 0 |
Fixed Bearing | each | 6 | 0 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1 | 0 | 1 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 240 | 240 | 0 | 0 | 0 |