I-64 EBL over CR 38 & GREENBRIER RIVER
Map
Coordinates:
+37.78946, -80.3844637°47'22" N, 80°23'04" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-64 EBL over CR 38 & GREENBRIER RIVER |
Structure number: | 00000000013A152 |
Location: | 2.57 Miles W. of CR 60/14 |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 163.4 ft. [49.8 m] |
Total length: | 821.9 ft. [250.5 m] |
Roadway width between curbs: | 40.4 ft. [12.3 m] |
Deck width edge-to-edge: | 44.6 ft. [13.6 m] |
Vertical clearance below bridge: | 55.8 ft. [17.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1967 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 5 |
Main spans material: | Steel continuous [4] |
Main spans design: | Girder and floorbeam system [03] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 10,771 [as of 2016] |
Truck traffic: | 28% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 95.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $1,266,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 10771 | 95.0 |
May 2016 | Fair | Good | Satisfactory | Satisfactory | 6000 | 93.1 |
May 2014 | Fair | Good | Satisfactory | Satisfactory | 6000 | 93.1 |
June 2013 | Fair | Satisfactory | Satisfactory | Good | 6000 | 93.1 |
July 2012 | Fair | Satisfactory | Good | Good | 5500 | 93.1 |
June 2011 | Fair | Satisfactory | Good | Good | 5500 | 93.1 |
June 2010 | Fair | Satisfactory | Satisfactory | Good | 5500 | 92.4 |
September 2008 | Fair | Satisfactory | Satisfactory | Good | 9100 | 96.1 |
August 2006 | Fair | Satisfactory | Good | Good | 7000 | 96.3 |
September 2004 | Fair | Satisfactory | Good | Good | 6500 | 92.3 |
August 2002 | Fair | Satisfactory | Good | Good | 7250 | 92.2 |
September 2000 | Fair | Satisfactory | Good | Good | 7500 | 92.2 |
September 1998 | Fair | Satisfactory | Good | Good | 5250 | 92.4 |
September 1996 | Good | Good | Good | Good | 5250 | 91.4 |
September 1994 | Good | Good | Good | Good | 5000 | 93.5 |
September 1992 | Good | Good | Good | Good | 6000 | 92.4 |
October 1990 | Good | Good | Good | Good | 9200 | 92.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 1,640 | 1,640 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 33,895 | 33,895 | 0 | 0 | 0 |
Steel Stringer | linear ft. | 3,280 | 3,280 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 22,210 | 22,210 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 36,400 | 36,400 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 36,400 | 36,368 | 32 | 0 | 0 |
Superstructure |
Steel Floor Beam | linear ft. | 935 | 935 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 14,535 | 14,535 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 90 | 90 | 0 | 0 | 0 |
Prestressed Concrete Pile | each | 8 | 8 | 0 | 0 | 0 |
Prestressed Concrete Pier Cap | linear ft. | 176 | 176 | 0 | 0 | 0 |
Joints |
Assembly without Seal Joint | linear ft. | 90 | 90 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 10 | 10 | 0 | 0 | 0 |
Fixed Bearing | each | 2 | 2 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,640 | 1,640 | 0 | 0 | 0 |