Share:

WV 09 X over WV 115 (old route 9)

Map

Coordinates:
+39.36512, -77.86972
39°21'54" N, 77°52'11" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WV 09 X over WV 115 (old route 9)
Structure number:00000000019A045
Location:0.25 MI W OF CR 08 SLS
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:146.0 ft. [44.5 m]
Total length:353.0 ft. [107.6 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.6 ft. [13.6 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:65°
Owner:State Highway Agency [01]
Year built:2006
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel continuous [4]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: January 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:21,696 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:99.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2018FairSatisfactorySatisfactorySatisfactory2169699.0
January 2016FairSatisfactorySatisfactorySatisfactory1247799.0
January 2014GoodVery GoodVery GoodVery Good1140099.0
January 2012GoodVery GoodVery GoodVery Good905099.0
January 2010GoodVery GoodVery GoodVery Good905098.1
January 2008GoodVery GoodExcellentExcellent925098.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,7301,59213800
Steel Protective Coatingsq. ft.26,560026,1840376
Deck
Reinforced Concrete Decksq. ft.14,800011,8222,9780
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.350127195280
Reinforced Concrete Pier Caplinear ft.200200000
Bearings
Elastomeric Bearingeach2020000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.708070800