Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | WV 34 over KANAWHA RV, WV62, N&S RR |
Structure number: | 00000000040A035 |
Location: | 0.31 MI N OF WV 817 |
Purpose: | Carries highway over highway, waterway, and railroad |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 462.0 ft. [140.8 m] |
Total length: | 1433.5 ft. [436.9 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 35.1 ft. [10.7 m] |
Vertical clearance above deck: | 13.8 ft. [4.2 m] |
Vertical clearance below bridge: | 59.1 ft. [18.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1955 |
Year reconstructed: | 2010 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel continuous [4] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 8,569 [as of 2015] |
Truck traffic: | 13% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Underclearances appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | None present but re-evaluation suggested [5] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 43.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Good | Fair | Good | 8569 | 43.3 |
October 2015 | Poor | Very Good | Serious | Good | 10000 | 17.3 |
November 2013 | Good | Excellent | Very Good | Very Good | 10000 | 54.3 |
October 2012 | Good | Excellent | Very Good | Very Good | 10000 | 56.3 |
December 2011 | Good | Excellent | Good | Good | 8000 | 62.8 |
September 2010 | Good | Excellent | Good | Good | 10000 | 56.2 |
October 2009 | Fair | Fair | Fair | Satisfactory | 10000 | 43.9 |
October 2008 | Fair | Fair | Fair | Satisfactory | 10000 | 43.9 |
September 2007 | Fair | Fair | Fair | Satisfactory | 10500 | 42.5 |
August 2006 | Fair | Fair | Fair | Satisfactory | 9000 | 28.0 |
November 2005 | Fair | Fair | Fair | Satisfactory | 9000 | 28.0 |
August 2004 | Fair | Fair | Fair | Satisfactory | 10000 | 28.0 |
September 2003 | Fair | Fair | Fair | Satisfactory | 8700 | 28.0 |
August 2002 | Fair | Fair | Fair | Satisfactory | 8700 | 28.0 |
August 2001 | Fair | Fair | Fair | Satisfactory | 8700 | 28.0 |
August 2000 | Fair | Good | Fair | Satisfactory | 8700 | 47.5 |
August 1999 | Fair | Good | Fair | Satisfactory | 8700 | 47.5 |
August 1998 | Fair | Good | Fair | Satisfactory | 8700 | 47.5 |
August 1997 | Fair | Good | Fair | Satisfactory | 8700 | 47.5 |
July 1996 | Fair | Good | Fair | Satisfactory | 7100 | 47.5 |
July 1995 | Fair | Good | Fair | Satisfactory | 7100 | 47.5 |
November 1994 | Poor | Poor | Fair | Satisfactory | 7600 | 46.5 |
August 1993 | Poor | Good | Fair | Poor | 7100 | 29.5 |
April 1992 | Fair | Good | Fair | Satisfactory | 7100 | 45.5 |
July 1991 | Poor | Serious | Fair | Satisfactory | 7100 | 40.5 |