I-64 EB over CR 40
Map
Coordinates:
+38.45565, -81.9796938°27'20" N, 81°58'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-64 EB over CR 40 |
Structure number: | 00000000040A067 |
Location: | 2.39 MI E OF CR 19 |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 49.9 ft. [15.2 m] |
Total length: | 132.9 ft. [40.5 m] |
Roadway width between curbs: | 38.7 ft. [11.8 m] |
Deck width edge-to-edge: | 42.3 ft. [12.9 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 18° |
Owner: | State Highway Agency [01] |
Year built: | 1959 |
Year reconstructed: | 1981 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel continuous [4] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 18,539 [as of 2015] |
Truck traffic: | 17% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 83.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $475,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Fair | Good | Fair | 18539 | 83.0 |
April 2015 | Fair | Fair | Good | Fair | 40583 | 83.0 |
May 2013 | Fair | Good | Good | Satisfactory | 38500 | 95.0 |
May 2011 | Good | Good | Good | Good | 38500 | 95.0 |
May 2009 | Good | Good | Good | Good | 20000 | 93.1 |
June 2007 | Good | Good | Good | Good | 21800 | 92.9 |
June 2005 | Good | Good | Good | Good | 20000 | 93.1 |
June 2003 | Good | Good | Good | Good | 18500 | 93.2 |
June 2001 | Good | Good | Good | Good | 17250 | 93.3 |
August 1999 | Good | Good | Very Good | Good | 17500 | 93.3 |
October 1997 | Good | Good | Very Good | Good | 16500 | 93.4 |
October 1995 | Good | Good | Very Good | Good | 15250 | 93.8 |
October 1993 | Good | Good | Good | Good | 13000 | 74.7 |
November 1991 | Good | Good | Good | Good | 13500 | 74.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 640 | 640 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,924 | 5,544 | 190 | 190 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 5,504 | 4,592 | 336 | 576 | 0 |
Substructure |
Reinforced Concrete Column | each | 4 | 4 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 88 | 63 | 9 | 16 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 80 | 79 | 0 | 1 | 0 |
Joints |
Strip Seal Joint | linear ft. | 82 | 52 | 5 | 0 | 25 |
Bearings |
Movable Bearing | each | 15 | 5 | 4 | 6 | 0 |
Fixed Bearing | each | 5 | 5 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 256 | 213 | 43 | 0 | 0 |