SHERIDN BL/FAU5214 over PEDESTRIAN WALKWAY
This bridge is no longer in the current National Bridge Inventory database, and has likely been demolished or abandoned.
Map
Coordinates:
+40.77500, -96.6700040°46'30" N, 96°40'12" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SHERIDN BL/FAU5214 over PEDESTRIAN WALKWAY |
Structure number: | U142503815L |
Location: | LINCOLN SHERIDAN @ 33RD |
Purpose: | Carries highway over pedestrian/bicycle trail |
Route classification: | Minor Arterial (Urban) [16] |
Length of largest span: | 49.9 ft. [15.2 m] |
Total length: | 136.2 ft. [41.5 m] |
Roadway width between curbs: | 22.0 ft. [6.7 m] |
Deck width edge-to-edge: | 30.2 ft. [9.2 m] |
Skew angle: | 10° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1934 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: May 2011
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 9,100 [as of 2008] |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of replacement [2] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 53.3 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $559,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2011 | Fair | Fair | Fair | Fair | 9100 | 53.3 |
May 2009 | Fair | Fair | Fair | Fair | 9100 | 42.9 |