Share:

US-54 HWY WB over RS 2420

Map

Coordinates:
+37.00083, -100.98583
37°00'03" N, 100°59'09" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US-54 HWY WB over RS 2420
Structure number:999905400880091
Location:.65 MI N OK STATE LN
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:78.7 ft. [24.0 m]
Total length:200.1 ft. [61.0 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:16°
Owner:State Highway Agency [01]
Year built:2005
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Not applicable [N]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:3,220 [as of 2017]
Truck traffic:30% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Better than present minimum criteria [7]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:100.0
Recommended work:Bridge deck replacement with only incidental widening. [37]
Estimated cost of work:$277,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018GoodGoodVery GoodVery Good3220100.0
April 2016GoodGoodVery GoodVery Good3080100.0
April 2014GoodGoodVery GoodVery Good3065100.0
April 2012GoodVery GoodVery GoodVery Good3135100.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,2021,202000
Deck
Reinforced Concrete Decksq. ft.8,4138,23716880
Wearing Surfacessq. ft.8,4138,23716880
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.8080000
Reinforced Concrete Pier Caplinear ft.8484000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.401401000