PARK DR. (CS-1234) over BEE CREEK
Map
Coordinates:
+36.62722, -88.3105636°37'38" N, 88°18'38" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | PARK DR. (CS-1234) over BEE CREEK |
Structure number: | 018C00145N |
Location: | .2 MI S. OF SOUTHWOOD |
Purpose: | Carries highway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 44.9 ft. [13.7 m] |
Total length: | 44.9 ft. [13.7 m] |
Roadway width between curbs: | 17.4 ft. [5.3 m] |
Deck width edge-to-edge: | 18.4 ft. [5.6 m] |
Skew angle: | 10° |
Owner: | County Highway Agency [02] |
Year built: | 1970 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Open Grating [3] |
Wearing surface: | Other [9] |
Latest Available Inspection: July 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 237 [as of 2012] |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 46.3 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2017 | Fair | Fair | Fair | Fair | 237 | 46.3 |
July 2015 | Fair | Fair | Fair | Fair | 237 | 45.0 |
July 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 237 | 53.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 269 | 0 | 134 | 135 | 0 |
Steel Protective Coating | sq. ft. | 1,779 | 0 | 889 | 890 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 42 | 0 | 34 | 8 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 21 | 0 | 21 | 0 | 0 |
Deck |
Open Grid Deck | sq. ft. | 829 | 0 | 0 | 829 | 0 |
Steel Protective Coating | sq. ft. | 4,145 | 0 | 0 | 4,145 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 90 | 0 | 90 | 0 | 0 |
Steel Protective Coating | sq. ft. | 450 | 0 | 450 | 0 | 0 |