OR 47 (HWY 110) over Creek
Map
Coordinates:
+46.10764, -123.2270846°06'28" N, 123°13'37" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | OR 47 (HWY 110) over Creek |
Structure number: | 20804 110 00125 |
Location: | HWY 110 MP 1.25 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 27.2 ft. [8.3 m] |
Total length: | 29.9 ft. [9.1 m] |
Roadway width between curbs: | 25.9 ft. [7.9 m] |
Deck width edge-to-edge: | 47.9 ft. [14.6 m] |
Owner: | State Highway Agency [01] |
Year built: | 2008 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Concrete [1] |
Main span design: | Culvert [19] |
Deck type: | Concrete Cast-in-Place [1] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 860 [as of 2017] |
Truck traffic: | 39% of total traffic |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 84.8 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
October 2018 | Good | 7 out of 10 | 860 | 84.8 |
November 2017 | Good | 7 out of 10 | 870 | 84.8 |
November 2015 | Good | 7 out of 10 | 650 | 91.5 |
November 2013 | Good | 7 out of 10 | 860 | 84.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 71 | 67 | 4 | 0 | 0 |