Share:

PA TPK (I-376) over SR4001, NORFOLK

Map

Coordinates:
+40.82075, -80.37142
40°49'15" N, 80°22'17" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PA TPK (I-376) over SR4001, NORFOLK
Structure number:000000000003800
Location:BIG BEAVER BOROUGH
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Other (Rural) [02]
Tolls:Yes, on toll road [2]
Length of largest span:149.9 ft. [45.7 m]
Total length:290.0 ft. [88.4 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:45.6 ft. [13.9 m]
Vertical clearance below bridge:39.4 ft. [12.0 m]
Skew angle:
Owner:State Toll Authority [31]
Year built:1992
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:9,871 [as of 1998]
Truck traffic:12% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present desirable criteria [8]
Underclearances appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:99.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017GoodGoodGoodGood987199.5
October 2015GoodGoodGoodGood987199.5
October 2013GoodGoodGoodGood987199.5
October 2011GoodGoodGoodGood987199.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,4251,3656000
Steel Protective Coatingsq. ft.22,08822,0280600
Deck
Reinforced Concrete Decksq. ft.13,11213,112000
Wearing Surfacessq. ft.12,10412,103100
Substructure
Reinforced Concrete Columneach33000
Reinforced Concrete Pier Walllinear ft.4848000
Reinforced Concrete Abutmentlinear ft.123012300
Reinforced Concrete Pier Caplinear ft.5050000
Joints
Strip Seal Jointlinear ft.9292000
Bearings
Pot Bearingeach1515000
Steel Protective Coatingsq. ft.4545000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.577577000