Share:

PR-994 over KIANI LAGOON

Map

Coordinates:
+18.14694, -65.55556
18°08'49" N, 65°33'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR-994 over KIANI LAGOON
Structure number:028521
Location:14 KM WEST OF ISABEL II
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:61.0 ft. [18.6 m]
Total length:61.0 ft. [18.6 m]
Roadway width between curbs:18.0 ft. [5.5 m]
Deck width edge-to-edge:18.0 ft. [5.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Steel plate (includes orthotropic) [5]
Wearing surface:Other [9]

Latest Available Inspection: December 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2005]
Truck traffic:5% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:84.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
December 2018GoodVery GoodVery GoodVery Good10084.0
January 2016GoodVery GoodVery GoodVery Good10084.0
January 2014GoodVery GoodVery GoodVery Good10084.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Trusslinear ft.312312000
Steel Floor Beamlinear ft.174174000
Substructure
Reinforced Concrete Abutmentlinear ft.4646000
Deck
Corrugated or Orthotropic Decksq. ft.1,0981,098000
Bearings
Movable Bearingeach44000