800 SOUTH ST. over SEVIER RIVER
Map
Coordinates:
+38.15714, -112.2778638°09'26" N, 112°16'40" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | 800 SOUTH ST. over SEVIER RIVER |
Structure number: | 031013C |
Location: | 800 SO.ST.IN CIRCLEVILLE |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 35.4 ft. [10.8 m] |
Total length: | 36.4 ft. [11.1 m] |
Roadway width between curbs: | 29.9 ft. [9.1 m] |
Deck width edge-to-edge: | 33.5 ft. [10.2 m] |
Skew angle: | 57° |
Owner: | Town or Township Highway Agency [03] |
Year built: | 2008 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Integral Concrete (separate non-modified layer of concrete added to structural deck) [2] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, posting recommended but not legally implemented [B] |
Average daily traffic: | 25 [as of 2010] |
Truck traffic: | 1% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 74.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Fair | Satisfactory | Satisfactory | Good | 25 | 74.2 |
May 2016 | Good | Good | Good | Good | 25 | 74.2 |
May 2014 | Good | Very Good | Good | Very Good | 25 | 100.0 |
May 2012 | Good | Very Good | Very Good | Very Good | 25 | 100.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 207 | 0 | 207 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 1,150 | 748 | 402 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 80 | 40 | 40 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 12 | 0 | 0 | 12 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 69 | 35 | 34 | 0 | 0 |