Share:

RTE. 11 over COLORADO ST O ROANOKE R

Map

Coordinates:
+37.27625, -80.05400
37°16'34" N, 80°03'14" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RTE. 11 over COLORADO ST O ROANOKE R
Structure number:000000000028529
Location:.97 MI. FROM INT 419
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:60.0 ft. [18.3 m]
Total length:163.1 ft. [49.7 m]
Roadway width between curbs:64.0 ft. [19.5 m]
Deck width edge-to-edge:83.0 ft. [25.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:18,958 [as of 2010]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:95.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017GoodGoodGoodGood1895895.3
June 2015GoodGoodGoodGood1895895.3
June 2013GoodGoodGoodGood1895895.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Pier Walllinear ft.172166600
Reinforced Concrete Abutmentlinear ft.2652422210
Joints
Compression Jointlinear ft.166166000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.447447000
Reinforced Concrete Bridge Raillinear ft.4545000
Deck
Reinforced Concrete Slabsq. ft.13,529013,52900