SH 3 over WILLOW CREEK
Map
Coordinates:
+47.45611, -116.6030647°27'22" N, 116°36'11" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SH 3 over WILLOW CREEK |
Structure number: | 000000000010126 |
Location: | 10.2 S. ROSE LAKE |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 52.2 ft. [15.9 m] |
Total length: | 55.1 ft. [16.8 m] |
Roadway width between curbs: | 37.1 ft. [11.3 m] |
Deck width edge-to-edge: | 40.0 ft. [12.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 2014 |
Historic significance: | Historical significance is not determinable at this time [4] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: July 2016
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,100 [as of 2015] |
Truck traffic: | 15% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 96.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2016 | Good | Very Good | Very Good | Very Good | 1100 | 96.9 |
November 2014 | Good | Excellent | Excellent | Excellent | 1100 | 96.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 423 | 423 | 0 | 0 | 0 |
Deck |
Prestressed Concrete Top Flange | sq. ft. | 2,200 | 2,200 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 2,035 | 2,035 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 2,035 | 2,035 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 93 | 84 | 9 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 107 | 107 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 150 | 150 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 110 | 110 | 0 | 0 | 0 |