LOCAL ROAD over TIGER BAYOU
Map
Coordinates:
+32.96229, -91.3396832°57'44" N, 91°20'23" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | LOCAL ROAD over TIGER BAYOU |
Structure number: | 056200000400091 |
Location: | 0.6 MILES WEST OF LA 17 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 9.8 ft. [3.0 m] |
Total length: | 24.0 ft. [7.3 m] |
Skew angle: | 16° |
Owner: | County Highway Agency [02] |
Year built: | 1999 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: February 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 200 [as of 1979] |
Structural appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Culvert condition: | Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 97.0 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
February 2017 | Fair | 6 out of 10 | 200 | 97.0 |
March 2015 | Fair | 6 out of 10 | 200 | 97.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Steel Culvert | linear ft. | 160 | 0 | 160 | 0 | 0 |
Steel Protective Coating | sq. ft. | 5,027 | 0 | 0 | 0 | 5,027 |