SR 105 over NORTH RIVER
Map
Coordinates:
+46.75144, -123.8884146°45'05" N, 123°53'18" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 105 over NORTH RIVER |
Structure number: | 0018345B0000000 |
Location: | 10.5 N JCT US 101 |
Purpose: | Carries highway over waterway |
Route classification: | Minor Arterial (Rural) [06] |
Length of largest span: | 160.1 ft. [48.8 m] |
Total length: | 600.1 ft. [182.9 m] |
Roadway width between curbs: | 36.1 ft. [11.0 m] |
Deck width edge-to-edge: | 38.7 ft. [11.8 m] |
Skew angle: | 30° |
Owner: | State Highway Agency [01] |
Year built: | 2014 |
Historic significance: | Historical significance is not determinable at this time [4] |
Number of main spans: | 4 |
Main spans material: | Prestressed concrete continuous [6] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 974 [as of 2016] |
Truck traffic: | 7% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 93.5 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $9,120,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Good | Very Good | Very Good | Very Good | 974 | 93.5 |
May 2016 | Good | Very Good | Very Good | Very Good | 1069 | 93.0 |
September 2014 | Good | Very Good | Very Good | Very Good | 1069 | 93.0 |