I-96 EB over US-23 SB
Map
Coordinates:
+42.52415, -83.7564942°31'27" N, 83°45'23" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-96 EB over US-23 SB |
Structure number: | 000000000013652 |
Location: | @ US-23 INTERCHANGE |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 170.0 ft. [51.8 m] |
Total length: | 173.9 ft. [53.0 m] |
Roadway width between curbs: | 47.9 ft. [14.6 m] |
Deck width edge-to-edge: | 51.2 ft. [15.6 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Skew angle: | 99° |
Owner: | State Highway Agency [01] |
Year built: | 2015 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Prestressed concrete [5] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: October 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 363,610 [as of 2012] |
Truck traffic: | 2% of total traffic |
Deck condition: | Excellent [9 out of 9] |
Superstructure condition: | Excellent [9 out of 9] |
Substructure condition: | Excellent [9 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Superior to present desirable criteria [9] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 85.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2017 | Good | Excellent | Excellent | Excellent | 363610 | 85.0 |
October 2015 | Good | Excellent | Excellent | Excellent | 363610 | 85.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 1,390 | 1,380 | 10 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 26,416 | 26,416 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 8,907 | 8,907 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 695 | 695 | 0 | 0 | 0 |
Substructure |
Other Material Abutment | linear ft. | 210 | 207 | 3 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 841 | 841 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 105 | 0 | 105 | 0 | 0 |
Pourable Joint | linear ft. | 201 | 201 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 16 | 16 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 348 | 323 | 25 | 0 | 0 |